You have no items in your shopping cart.
1 Year Warranty Best Price Guaranteed Fast Delivery 100% Satisfied Customers

Automatic Self Cleaning Horizontal Filters

Body Material : St-37 – AISI 316L
Screen Material : AISI 304L – CAGEPRGF
Maximum Working Pressure : 8 bar
Minimum Output Pressure : 2.5 bar
Maximum Working Temperature : 60°C
Back Wash Time : Timing and Pressure Setup
Control System : Electric or Hydraulic Control
The Filtration Sensitivity : 100, 130, 200 micron
Paint Material : Epoxy polyester
Made in : Turkey
3.023,00 €
3.393,00 €
Manufacturer: Armas Valves & Filters
SKU: HSF-AUTO
Delivery date 2-3 business days
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
*
*
+ -

ARMAS AutoFlush Automatic Horizontal Screen Filter

APPLICATIONS

  • Agricultural Applications
  • Industrial Applications
  • Municipal Applications
  • Water Management
  • Cooling Towers

FEATURES

  • Automatic self-cleaning system
  • Reliability: Efficient filtration at various flow rates
  • Most efficient filtration method
  • Low head loss
  • Uninterrupted filtration during self-cleaning
  • Low maintenance cost

 

OPERATION PRINCIPLE

AutoFlush® series can do automatic cleaning without any need for external power supply or optionally with electrical activation from a distance. The filter screen can achieve filtration rates from 25 m3/h to 180 m3/h. Standard filter screen size is 130 microns and inlet/exit pipe diameters are available between 2” to 8”.

Armas Autoflush horizontal filter inner

FILTRATION METHOD

Filtration starts as the dirty water enters the coarse screen from the inlet. In order to protect the fine filter, large particles are filtered on the coarse filter. Water then passes through the fine filter, particles are captured by the fine filter, and clean water leaves from the outlet. Particles gradually accumulating on the fine filter, increases the pressure difference. Once the pressure difference exceeds the preset pressure differential value, filter automatically starts to clean itself.

CLEANING METHOD

Once the pressure difference exceeds the preset pressure differential value, hydraulic control unit opens the drainage valve and the cleaning cycle starts. Particles accumulated on the fine filter, are sucked by the nozzles and the turbine and discharged from the drainage pipe. Thus cleaning operation is achieved. Filtration is not interrupted and AutoFlush® continues filtration during the cleaning cycle.

 

 Download Product Catalogue

 

Material List

 

Armas Autoflush horizontal automatic parts Part No Part Name
1 Body
2 Bonnet and piston mechanism
3 Screen and filter group
4 Suction nozzle set
5 Coarse filter
6 Bonnet
7 Hydraulic control unit
8 Stainless steel nut
9 Stainless steel bolt

 

Available Models and Recommended Flow Rates

 

Model Max Flow Rate (m3/h) Inlet/Outlet Dimension (inch) Filtration Degree Min. Operation Pressure (bar) Max. Operation Pressure (bar) Temp. Cleaning Cycle Time Cleaning Criteria Filtration Area (cm2)
HSF-100 100m3/h 4" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2
HSF-120 120 m3/h 5" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2
HSF-160 160 m3/h 6" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2
HSF-180 180 m3/h 8" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2

 

Technical Specifications

 

Autoflush automatic horizontal filter dimensions Product Code ØD L1 L2 L3 Flow Rate Filter Surface Weight
  inch mm mm mm mm m3/h cm2 kg
HSF-100 4" 100 900 1894 2400 100 6800 92
HSF-120 5" 125 900 1894 2400 120 6800 127
HSF-160 6" 150 900 1894 2400 160 6800 145
HSF-180 8" 200 900 1894 2400 180 6800 152

 

Head Loss Chart & Sample Application

 

Autoflush automatic horizontal filter curve Autoflush automatic horizontal screen filter sample

The Set Includes:

Grooved End Clamps, Hydrocyclone, Air Valves, Pressure Gauges, Ball Valves, Connection Equipments, Quick Pressure Relief Valve (QR) and Pressure Sustaining Valve (PS)

ARMAS AutoFlush Automatic Horizontal Screen Filter

APPLICATIONS

  • Agricultural Applications
  • Industrial Applications
  • Municipal Applications
  • Water Management
  • Cooling Towers

FEATURES

  • Automatic self-cleaning system
  • Reliability: Efficient filtration at various flow rates
  • Most efficient filtration method
  • Low head loss
  • Uninterrupted filtration during self-cleaning
  • Low maintenance cost

 

OPERATION PRINCIPLE

AutoFlush® series can do automatic cleaning without any need for external power supply or optionally with electrical activation from a distance. The filter screen can achieve filtration rates from 25 m3/h to 180 m3/h. Standard filter screen size is 130 microns and inlet/exit pipe diameters are available between 2” to 8”.

Armas Autoflush horizontal filter inner

FILTRATION METHOD

Filtration starts as the dirty water enters the coarse screen from the inlet. In order to protect the fine filter, large particles are filtered on the coarse filter. Water then passes through the fine filter, particles are captured by the fine filter, and clean water leaves from the outlet. Particles gradually accumulating on the fine filter, increases the pressure difference. Once the pressure difference exceeds the preset pressure differential value, filter automatically starts to clean itself.

CLEANING METHOD

Once the pressure difference exceeds the preset pressure differential value, hydraulic control unit opens the drainage valve and the cleaning cycle starts. Particles accumulated on the fine filter, are sucked by the nozzles and the turbine and discharged from the drainage pipe. Thus cleaning operation is achieved. Filtration is not interrupted and AutoFlush® continues filtration during the cleaning cycle.

 

 Download Product Catalogue

 

Material List

 

Armas Autoflush horizontal automatic parts Part No Part Name
1 Body
2 Bonnet and piston mechanism
3 Screen and filter group
4 Suction nozzle set
5 Coarse filter
6 Bonnet
7 Hydraulic control unit
8 Stainless steel nut
9 Stainless steel bolt

 

Available Models and Recommended Flow Rates

 

Model Max Flow Rate (m3/h) Inlet/Outlet Dimension (inch) Filtration Degree Min. Operation Pressure (bar) Max. Operation Pressure (bar) Temp. Cleaning Cycle Time Cleaning Criteria Filtration Area (cm2)
HSF-100 100m3/h 4" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2
HSF-120 120 m3/h 5" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2
HSF-160 160 m3/h 6" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2
HSF-180 180 m3/h 8" 130 micron 2.5 bar 8 bar 60℃ 15-22 sec Differential
Pressure
0.5 bar
6800 cm2

 

Technical Specifications

 

Autoflush automatic horizontal filter dimensions Product Code ØD L1 L2 L3 Flow Rate Filter Surface Weight
  inch mm mm mm mm m3/h cm2 kg
HSF-100 4" 100 900 1894 2400 100 6800 92
HSF-120 5" 125 900 1894 2400 120 6800 127
HSF-160 6" 150 900 1894 2400 160 6800 145
HSF-180 8" 200 900 1894 2400 180 6800 152

 

Head Loss Chart & Sample Application

 

Autoflush automatic horizontal filter curve Autoflush automatic horizontal screen filter sample

The Set Includes:

Grooved End Clamps, Hydrocyclone, Air Valves, Pressure Gauges, Ball Valves, Connection Equipments, Quick Pressure Relief Valve (QR) and Pressure Sustaining Valve (PS)

Please click here to be redirected to your nearest store and get the best deals! Close